# Configure ACC data inputs manually

# Configure ACC data inputs manually {#ariaid-title1}

* Release version: Yokohama
* 
* Updated January 30, 2025
* 
* ![](https://www.servicenow.com/docs/portal-asset/ico-clock) 2 minutes to read

Agent Client Collector setup automatically creates an ACC data input
for streaming log messages to your ServiceNow instance. You can set up
additional ACC data inputs manually as needed.

## Before you begin

* The Agent Client Collector Log Analytics application has a dependency on the following ServiceNow applications, available from the [ServiceNow Store](https://store.servicenow.com/sn_appstore_store.do#!/store/home):
  * Health Log Analytics, Version 22.0.12 - December 2021 and later releases.
  * Agent Client Collector -Framework, Version 2.7.0 - December 2021 and later releases.
  {#hla-data-input-acc__ul_hnx_bjn_rqb}
* Verify that a MID Server is installed and configured. For more information, see [MID Server system requirements](https://www.servicenow.com/docs/access?context=r_MIDServerSystemRequirements&version=yokohama&pubname=yokohama-servicenow-platform&ft:locale=en-US).
* The MID Server must be configured to work with the Agent Client Collector. For more information, see [Enable Agent Client Collector monitoring on the MID Server](https://servicenow-prod.fluidtopics.net/AT1P4nAEwMMFFW~n8utcDQ "Enable Agent Client Collector monitoring on the MID Server by configuring the Agent Client Collector framework (ACC-F) and Metric Intelligence extensions in a single action. Enabling Agent Client Collector monitoring also enables monitoring on agents connected to the MID Server.").
{#hla-data-input-acc__ul_zkp_qch_kqb}  
Important:  
Health Log Analytics does not support IPv6. To work with the application, configure the MID Server to IPv4.  
Note:  
Currently, this setup only supports basic authentication with the MID Server. mTLS is not supported.

Role required: evt_mgmt_admin

## Procedure

1. Navigate to AllACC Log AnalyticsACC Data Inputs.
2. Select New.
3. On the form, fill in the fields.  
   For a description of the fields, see [ACC data input configuration fields](https://servicenow-prod.fluidtopics.net/kYEXHytUfSBBFt74X5W3eA "Description of the fields on the ACC data input configuration form.").
4. **Optional:** Select Advanced to set additional configuration fields.
5. Select Save.  
   Health Log Analytics adds the data input record to the Data Inputs table.
6. Ensure that the data input is configured correctly by selecting Test connection.  
   Health Log Analytics tries to connect the MID Server to the data repository.  
   * If the connection was established, the Test connection button is turned off and the Publish button is enabled.
   * If the connection failed, the reason for the failure displays in the Error message field. This field displays only when a streaming error has occurred.

     Resolve the issue, select
     Save if you modified the configuration, and then select Test connection to test the connection again.  
     Note:  
     You can only publish the data input configuration when the connection is created successfully.

   {#hla-data-input-acc__ul_z2d_sxt_r5b}  
   Note:  
   You can revert to the last published configuration by selecting Revert Changes. This option is available only when you're modifying a configuration that has been published previously.
7. Select Publish to publish the data input to the MID Server.
{#hla-data-input-acc__steps_t34_csw_nqb}

## Result

The new data input is ready to stream logs.  
Note:  
The data input record includes these related lists:

* Agents -- Lists all active agents connected to the MID Server for this data input.
* Streaming Sources -- Lists all sources for this data input and the MID Server that receives logs from it.
{#hla-data-input-acc__ul_qs2_3j1_5qb}

## What to do next

[Ensure
that the data input is streaming data](https://servicenow-prod.fluidtopics.net/oOfiw4LViA_6PhNwfUsPKQ "Make sure that your ACC data inputs are streaming data properly by identifying and resolving log streaming issues.").

*[\>]: and then