# Map LogRhythm alarm fields to security incident fields

# Map LogRhythm alarm fields to
security incident fields {#ariaid-title1}

* Release version: Australia
* 
* Updated March 12, 2026
* 
* ![](https://www.servicenow.com/docs/portal-asset/ico-clock) 5 minutes to read

You map individual alarm fields to the security incident fields. The preconfigured
mapping can be edited, and color coding provided for the fields helps you monitor alarms you
have already mapped. This step helps you visualize how your edits impact the fields on the
security incident.

## Before you begin

Role required: sn_si.admin

If you are unfamiliar with the LogRhythm
alarms, navigate to the LogRhythm Client Console and review a few
sample Alarm IDs. For the following example, LogRhythm alarms
<kbd class="ph userinput">9468</kbd> and <kbd class="ph userinput">9474</kbd> were used to map the
alarms to the security incident.

## About this task

Using this form, you map the LogRhythm alarm rules on the left to the security incident fields on the right.

The following figure shows the default
mapping of alarms that is preconfigured for each alarm profile. This default mapping
can be edited, and with this form, you customize the fields that populate the
security incident. After you complete this mapping, you can see how adding or
removing alarm fields potentially impacts the field values on the security incident.

On the left side of this form in the following figure, the LogRhythm alarm rules are
outlined. The values of these alarm rules are mapped to the security incident fields
on the right side of the form.

## Procedure

1. After creating an alarm profile for LogRhythm, click Mapping on the progress bar.
2. In the Alarm Sample Ingestion field, enter up to five sample LogRhythm Alarm IDs separated by commas (<kbd class="ph userinput">9468,9474</kbd>).  
3. Next to the alarm field, click Pull Alarms.  
   The pull for sample alarms may take a few moments. A message indicating that
   the transaction is working is displayed at the top of the screen.  
   After the sample Alarm IDs are submitted and successfully pulled from the LogRhythm server, the alarm fields and their corresponding values are displayed in tabs.  
   Note:  
   After an alarm ID is successfully pulled, the ServiceNow AI Platform may return the following message: The following new fields will be available for filtering shortly. Please reload this profile in a few minutes if filtering based on these fields is required. itemspacketsin, itemspacketsout.

   This message occurs when the single
   alarm that has been pulled contains field names not previously processed
   by the ServiceNow AI Platform. These fields are available for mapping,
   however, if this message is displayed, reload the form so that these
   fields are displayed and available in the filter choice lists of the
   conditions builder when you are ready to set filtering
   conditions.

   Ingesting these sample alarms in the alarm profile
   configuration helps you prevent mapping alarm fields to the security
   incident that contain no values. It also aligns alarm fields with values to
   the appropriate fields in the security incident. This step ensures that all
   critical alarm fields are mapped and that there are no missing field values
   on the security incident.

   To help you ensure that no alarms are
   overlooked or duplicated in the mapping process, alarm fields are
   color-coded. A light blue alarm field (Account,
   AlarmRuleID,
   AlarmStatus, etc.) indicates that a field
   is not yet selected for mapping to a security incident.

   A gray field
   (AlarmDate,
   AlarmID, and
   AlarmRuleName) indicates that a field has
   already been selected and has been mapped to a field on the security
   incident. This color coding helps you track the mapping, because in certain
   cases, an alarm field can be mapped to more than one field on a security
   incident. For instance, the Observables and
   Work Note fields can have more than one
   value.
4. To clear the sample alarm data, click Clear Sample Alarm Data.
5. To edit the default configuration on the security incident, follow these steps to add a field:  
   1. On the lower right of the form, click the plus icon.  
      A new field is displayed.
   2. In the Security Incident column, select an available field from the choice list.  
      In the expanded choice list, some of the fields are shaded. For
      example, Category has a gray
      background, which indicates it has been mapped in the security
      incident. Similar to the color coding for LogRhythm
      alarm fields, this color coding for the security incident fields
      ensures that values from the alarm fields are not inadvertently
      mapped to the same security incident field.

      In the illustration above, the alarm rule
      ${Alarm:classificationName}$ is
      already mapped to the Category field in
      the security incident in this profile.  
      Note:  
      The Observable field can be mapped to more than field on the same security incident so that multiple observables can be displayed. Similarly, the Configuration Item and Work notes fields can be mapped to display multiple values.

      On the Alarm Sample Ingestion side of
      the form, blue indicates that an alarm rule field has not been
      mapped. Gray indicates that it has been mapped. In the choice
      list on the SIR Incident Field Mapping side of the form, white
      indicates that a field has not been mapped. Gray indicates that
      a field has been mapped. Use this color coding to help you track
      your field mapping.

      In the above illustration, Affected user
      has been selected from the choice list as a new field on the
      security incident.
   3. From the Alarm Sample Ingestion section on the left side of the form, left-click to select the Alarm ID you want in the Input Expression field.  
      In the above illustration, Login has
      been selected.
   4. Drag it to the cleared field and release it.  
      In the left column in the SIR Incident Field Mapping section, the new value for the Affected User field is displayed. In this case, the Login value from the LogRhythm alarm is displayed in the Affected user field on the security incident.
   {#logrhythm-map-alarms__substeps_ph3_ymt_32b}
6. Alternatively, to manually enter a value for fields in the Input Expression column, place your cursor in the input expression field, and enter a desired alarm value.  
   For example, in the above illustration another field has been added
   (<kbd class="ph userinput">Assignment group</kbd>) to the security incident form,
   and <kbd class="ph userinput">Security Incident Assignment</kbd> has been entered
   manually in the field.
7. Continue editing the preconfigured mapping as required.  
   If you need to translate values from LogRhythm alarm fields to values that are supported by the fields on the security incident, you can use the script editor. See [Use the script editor to format LogRhythm values](https://servicenow-prod.fluidtopics.net/FU~SHnefTHeZOyl2RXy0Gg "In addition to the directly mapped fields from the pulled alarm values, and the alarm values you enter manually, you can use the script editor to format field values on the security incident during the mapping step which is optional.").

## What to do next

After you complete the field mapping, the next step is to [Filter alarms for LogRhythm](https://servicenow-prod.fluidtopics.net/4fL2GQ1Am7OIz6jV1j_EkQ "Setting filtering criteria for alarms after you have mapped fields helps you determine which alarms should be ingested into the SIR application. Filtering alarms helps you significantly reduce the number of alarms you ingest when the alarm profile is activated.").