---
sourceDocument: Australia Security Management
sourceDocumentLink: https://servicenow-prod.fluidtopics.net/r/security-management

 Release :

    - australia

ft:locale :

    - en-US

ft:publication_title :

    - Australia Security Management

ft:clusterId :

    - security

bundleId :

    - security

workflow :

    - Technology


---

# Modify Qualys PC Results start date

# Modify Qualys PC Results start date {#ariaid-title1}

* Release version: Australia
* 
* Updated March 12, 2026
* 
* ![](https://www.servicenow.com/docs/portal-asset/ico-clock) 1 minute to read

If data is missing for the start date in the Qualys PC Results import, it can be
modified.

## Before you begin

Role required: sn_vul_qualys.admin

## Procedure

1. Navigate to AllQualys Vulnerability IntegrationAdministrationPrimary Integrations.
2. Click Qualys PC Results integration.
3. Click Integration Details.
4. Set the Start time field to a value in the past, so all scanned and detected test results, since that time, are detected.  
   Note:  
   If the date is left empty, no data is returned on the first run. Set the value to a maximum of a month in the past. This setting keeps large amount of data from exceeding the Qualys API rate limitations, as well as triggering execution timeouts.
5. Click Submit or Update.
6. **Optional:** Click Execute Now to run immediately.
{#modify-test-results-startdate__steps_trg_mxr_3v}

*[\>]: and then


