---
sourceDocument: Australia Platform Analytics
sourceDocumentLink: https://servicenow-prod.fluidtopics.net/r/de-DE/now-intelligence

 Release :

    - australia

ft:locale :

    - de-DE

ft:publication_title :

    - Australia Platform Analytics

ft:clusterId :

    - par

bundleId :

    - par

workflow :

    - Platform


---

# Data Visualization properties

# Data Visualization properties {#ariaid-title1}

* Freigeben Version: Australia
* 
* Aktualisiert 12. März 2026
* 
* ![](https://www.servicenow.com/docs/portal-asset/ico-clock) 1 Minute Lesedauer

Several properties that limit what can be displayed in data visualizations.
These Platform Analytics data visualization properties are available in the System Properties \[sys_properties\] table.  
Hinweis:  
To open the System Properties table, enter <kbd class="ph userinput">sys_properties.list.do</kbd> in the navigation filter.
{#data-visualization-properties__table_zjb_bhr_3dc__entry__2}

| Property | Description |
|-|-|
| com.glide.par.pae.drilldown_to_core_ui | Applies only to Platform Analytics experience: When true, Go to data chart interactions for visualizations of tables open the Core UI list of table records. Redirections in general that open lists or visualizations open Core UI lists and visualizations. When false, Go to data chart interactions for visualizations of tables open the Platform Analytics list of table records. Redirections in general that open lists or charts open Platform Analytics lists and charts. For more information, see [Chart interactions in a data visualization](https://servicenow-prod.fluidtopics.net/eKbxb9Eq2uB7N9lTFZzzwQ "You can set what occurs when a user interacts with a visualization, such as by selecting a bar column. Possibilities include navigating to a URL, opening another data visualization, and filtering all visualizations on the dashboard by the selected value."). * Type: true \| false (Boolean) * Default value: true * Location: System Property \[sys_properties\] table {#data-visualization-properties__ul_qdr_jq1_42c} |
| par_vis_config.data_source.can_select_indicator | Specifies roles (comma-separated) which can select indicators as data sources from the Data Visualization configuration panel. If empty, all users can select the indicator sources that they have access to. * Type: string * Default value: empty * Location: System Property \[sys_properties\] table {#data-visualization-properties__ul_akb_bhr_3dc} |
| par_vis_config.live_refresh_rate_min_value | Specifies the minimum interval in seconds for the Live refresh rate setting in the Data Visualization configuration. If set, a user can still set an empty or 0 value. * Type: integer * Default value: 30 (seconds) * Location: System Property \[sys_properties\] table {#data-visualization-properties__ul_tzv_g3r_3dc} |
| par_viz.table_data.max_data_points | Maximum number of data points for data visualizations based on table sources. * Type: integer * Default value: 10000 * Location: System Property \[sys_properties\] table {#data-visualization-properties__ul_rzl_t3r_3dc} |
| par_viz.table_data.max_groups | Maximum setting recognized for the maxNumberOfGroups property of data visualizations that have a Group by. Applies only to table data. * Type: integer * Default value: 50 * Location: System Property \[sys_properties\] table {#data-visualization-properties__ul_lgs_ljr_3dc} |
[Tabelle : 1. Properties for Data visualizations]

{#data-visualization-properties__table_zjb_bhr_3dc}

